Adjusting The Play In The Rotation Of The Loop Supply Slide Base - JUKI MOL-254 Engineer's Manual

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

Standard Adjustment

2) Adjusting the play in the rotation of the loop supply slide base

Adjust so that the play in the loop supply slide base in terms of the rotating direction should be 0.1 mm
or less at the shoulder portion of the loop supply slide base.
0.1 mm or less
0.1 mm or less
109