JUKI MOL-254 Engineer's Manual page 91

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

Adjustment Procedures
5. Remove the cover located on the right side of operation
box panel and turn ON SW 6 of the lower side of the DIP
switches which are located both on upper and lower sides.
6. Move the knife unit guide rail to the rear as long as the
length (a) of the triangle portion of cross cutting. Refer to
the figure on the left side.)
(Adjust the folding length on this side.)
(Caution) Dimension "a" will change according to the
loop width. Perform the work after confirming
how long the knife unit guide rail may be
moved before changing the length.
Results of Improper Adjustment
Approximate value
Loop width
84
Dimension "a"
9
3.3
10
3.7
11
4.1
12
4.4
13
4.8
14
5.2
15
5.5
16
5.9
17
6.3
19
7.0
20
7.4