JUKI MOL-254 Engineer's Manual page 67

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

19.Loosen setscrews
At this time, loosen two setscrews only on ball spline side
20.Remove setscrews
At this time, take care not to allow the spline shaft to slip from the ball nut.
21.Loosen setscrew
in oscillating eccentric shaft
22.Loosen setscrews
thrust collar
.
23.Remove E-ring
and remove the oscillating eccentric shaft in the direction of the arrow mark.
The timing belt can be removed through the aforementioned procedure.
Disassembling / Assembling
in ball spline connecting collar
in ball spline
and remove the ball spline in the direction of the arrow mark.
in thrust collar
of oscillating eccentric shaft
60
.
.
.
and loosen setscrews
in

Hide quick links: