JUKI MOL-254 Engineer's Manual page 83

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

Adjustment Procedures
1. Remove the cover from the feed gear.
2. Loosen two setscrews
move knife device bracket
height of the top surfaces.
in the knife device bracket and
up or down to adjust the
76
Results of Improper Adjustment
○ If the height of the top surface of
the loop clamp base plate is
different from that of the loop cut
counter knife, the loop clamp unit
may not be able to securely
catch the belt or defective
winding after drawing out the belt
will result.