2-7. Installing the power switch

WARNING :
1. Be sure to attach the ground wire (green/yellow) to the specified location (on the ground side).
2. Take care not to allow terminals to come in contact with each other.
3. When closing the power switch cover, take care not to allow the cord to be caught under it.

2-7-1. 3-phase 200 to 240V, Single phase 100 to 120V

Voltage specifications at the time of delivery from the factory are indicated on the voltage indication seal.
Connect the cord in accordance with the specifications.
– 9 –
1) Installing the power switch
Fix power switch ❶ under the machine table with
wood screws ❷ .
Fix the cable with staples ❸ supplied with the ma-
chine as accessories in accordance with the forms
of use.
Do not insert the power plug into the
plug receptacle.
2) Remove screw ❹ on the side face of the power
switch cover to open the power switch cover.
3) Pass AC input cord ❺ ,through the rear face of
the power switch. Bundle the cord with cable clip
band ❻ to secure it.