7-6
Cabling for Wide-Ultra SCSI-3
Determining Cabling Needs
To determine the SCSI cables needed for your application, follow the procedure
below:
1.
Determine whether the cabling needs are internal or external.
2.
Determine whether external cabling needs are for primary storage
(hard drive) or for secondary storage (tape drive or CD-ROM in the
removable media bay).
3.
Identify the controller type.
4.
Identify the drive type, drive cage, and expansion slot to be used.
5.
Refer to the appropriate entry in the SCSI Cable Usage Matrix in this
chapter to determine the correct usage and routing of the cables for your
configuration.
NOTE:
supported by Compaq ProLiant 5500 and 5500R servers.
For the latest information on SCSI controllers and configurations supported on
the Compaq ProLiant 5500 and 5500R server, see the following URL:
www.compaq.com.
IDE Controller
Compaq ProLiant 5500 and 5500R servers ship standard with a CD-ROM drive
in the removable media bay. Figure 7-4 shows the connection for the CD-ROM
signal cable and power cable.
Wide-Ultra SCSI-3 Hard Drive
Fast-Wide SCSI-2 Hard Drive
Fast SCSI-2 Hard Drive
Tape Drive
SCSI CD-ROM
Only those controllers listed in the SCSI Cable Usage Matrix are
For use with Pentium II Xeon and Pentium III Xeon processor-based servers only