Grounding Methods - Compaq ProLiant 5500 Setup And Installation Manual

Pentium ii xeon and pentium iii xeon processor-based servers
Hide thumbs Also See for ProLiant 5500:
Table of Contents

Advertisement

B-2 Electrostatic Discharge

Grounding Methods

There are several methods for grounding. Use one or more of the following
methods when handling or installing electrostatic-sensitive parts:
If you do not have any of the suggested equipment for proper grounding, have
an Authorized Compaq Reseller install the part.
Use a wrist strap connected by a ground cord to a grounded workstation
or computer chassis. Wrist straps are flexible straps with a minimum of
1 megohm ± 10 percent resistance in the ground cords. To provide
proper ground, wear the strap snug against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear
the straps on both feet when standing on conductive floors or dissipating
floor mats.
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating
work mat.
NOTE: For more information on static electricity, or assistance with product
installation, contact your Authorized Compaq Reseller.
For use with Pentium II Xeon and Pentium III Xeon processor-based servers only