FAQ

Error message
Memory card is not inserted (See
note.)*
Insufficient free space of memory
card (See note.)*
Insufficient flash memory.*
Insufficient model memory.*
Insufficient work memory.*
Incorrect region settings.
Loaded file error.*
Note *The ERR signal will turn ON for the items marked with an asterisk in the
7-4

FAQ

I/O
Question
Will the RUN signal be output during scene switching? - The RUN signal will remain ON during scene switch-
Will the RUN signal turn OFF when the ERROR signal
turns ON with Camera or other errors in Run Mode?
Why does the ERR signal turn ON when no error mes-
sage has been displayed?
Controller Operation
Question
What happens to expressions used in measurement
region data when a measurement region is cleared?
How do I set a formula with more than 64 characters in
an output expression?
What data is saved to flash memory or the Memory
Card when the save operation is executed?
Why are the Camera coordinates output to the external
device when calibration is set?
328
Insert the recommended Memory Card.
- Delete unnecessary files to create free space.
- Replace the Memory Card with a bigger capacity card.
- Make the region to be registered smaller.
- Delete unnecessary scenes and detection items.
- Make the region to be registered smaller.
- Delete unnecessary scenes and detection items.
- Make the region to be registered smaller.
- Delete unnecessary scenes and detection items.
The region is not drawn correctly. Draw the region again.
Specify the correct file and reload.
Reason:
- A formatting error may have occurred during data or program
file load.
- Data 2MG or greater cannot be loaded using serial communi-
cations. Load the data using the Memory Card.
above table, in Monitor Mode or Run Mode.
Causes and remedies
Answer
ing in Run Mode.
- The RUN signal will remain OFF during scene switch-
ing in Monitor Mode.
The RUN signal will remain ON even if the ERROR sig-
nal turns ON.
The ERR signal turns ON when STEP is input while the
BUSY signal is ON.
Select whether or not the ERR signal will turn ON
under SYS/Measurement control. Refer to page 314.
Answer
The expression settings will remain the same.
The result of the expression will be 0.000.
Set long expressions under Variable and set an output
expression that will browse multiple expressions.
Refer to page 211.
System data and the scene data for scene group 0 is
saved to flash memory. Scene data for scene groups 1
to 31 is overwritten to the Memory Card.
Check that Calibration under Coordinate mode for
each measurement item is set to ON.
If Calibration is set to OFF for a measurement item, the
Camera coordinates will be output.
Section 7-4
Refer-
ences
Setup
Expert:
page 279
Expert:
page 247
page 255
-
Expert:
page 247
page 255
-
Expert:
page 258