STEP 3: Changing Detailed Conditions

SeeAlso
1.
Select Judgement conditions.
0.Relative search
Model 0 setting
Model 1 setting
Judgement conditions
Detailed conditions
Coordinate mode
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
Correlation 0 : 79 [ 60 : 100 ]
Correlation 1 : 82 [ 60 : 100 ]
Width X(1-0) :
[
0.000 :
Width Y(1-0) :
[
0.000 :
Distance
:
[
0.000 :
End
2.
Make the settings for each item.
Refer to page 29 for details on inputting values.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Search-related settings can be changed under Detailed conditions. Change
the detailed conditions when the measurement results are unstable and to
increase processing speed. Normally, these conditions can be left at the
default settings.
After changing the settings, perform an object measurement to check that
measurement can still be performed correctly.
Refer to page 108 for information on each setting item.
1.
Select Detailed conditions.
0.Relative search
Model 0 setting
Model 1 setting
Judgement conditions
Detailed conditions
Coordinate mode
The Detailed Conditions Settings Screen will be displayed.
85..737
511.000]
62.239
483.000]
109.737
704.556]
Section 3-14
171