Density Data
3-6-5
STEP 5: Setting the Coordinate Mode
Coordinate mode
Output coordinate:
After scroll
Calibration
End
The default settings are marked with asterisks.*
CHECK
3-7
Density Data
SeeAlso
Select the type of coordinates.
Before scroll: Output made using the coordinate values
After scroll*: Output made using the coordinate values
Refer to page 197 for position compensation.
Refer to page 322 for differences between output coordinates.
: OFF
ON : Output made using coordinate values set using calibration.
OFF*: Output made using Camera coordinate values.
If the coordinate mode is changed after the judgement conditions have been
set, the measurement results will change also. Change the judgement condi-
tions to enable correct measurement.
1.
Select Coordinate mode.
0.Defect
Region
Reference registration
Judgement conditions
Detailed conditions
Coordinate mode
The Coordinate Mode Settings Screen will be displayed.
Coordinate mode
Output coordinate :
After scroll
Calibration
End
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
This function detects the density of each pixel (0 to 255) and calculates the
density average and deviation to be used for inspection.
Refer to page 9.
before position displacement compensation.
after position displacement compensation.
Refer to page 185 for information on calibration.
: OFF
Section 3-7
117