Selecting Items To Be Shown In Overall Judgements - Omron F160 Operation Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Selecting Items to be Shown in Overall Judgements

6-8

Selecting Items to be Shown in Overall Judgements

CHECK
SeeAlso
The Measurement Control Settings Screen will be displayed.
Measurement control
Image storage
STEP in measure
BUSY range
Reflect position
Reflect region
Reflect variable
Reflect judge
End
2.
Change the STEP in measure and BUSY range settings.
3.
Select End.
The settings are registered and the System Mode Screen will return.
Select which of the following four items will be shown in the overall judgement
output to the OR signal of the parallel interface.
• Position compensation judgement result
• Judgement result for each region
• Expression/Variable judgement result
• Expression/Judge judgement result
The overall judgement is displayed at the top of the Monitor and Run Mode
screens. The display conditions can be changed so that the overall judge-
ment will not be displayed. Refer to page 290.
0.Scn 0
MON
1.
Enter System mode and select Measurement control.
Refer to page 284.
:
None
:
ERR ON
:
Measurement
:
ON
:
ON
:
OFF
:
ON
OK
100ms
Freeze
Section 6-8
315

Advertisement

Table of Contents
loading

Table of Contents