Step 3: Changing The Search Coordinates - Omron F160 Operation Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Rotation Search
CHECK
3-15-3

STEP 3: Changing the Search Coordinates

CHECK
CHECK
178
To re-register models, repeat from step 1 under Step 2: Registering Mod-
els.
Use this function to change the search coordinates only.
When a model is registered, the center position of the model is registered as
the search coordinates. However, this function can be used to register a point
other than the center of the model as the search coordinates.
The search coordinates are used for the point output as the measurement
value. This point can be changed to any suitable point.
Changing the Point Output as the Measurement Value
Model
If the model is re-registered, the search coordinates are changed to the center
position of the new model.
1.
Select Search coordinates.
0.Rotation search
Measurement conditions
Model registration
Search coordinate
A
Search region
Judgement conditions
Detailed conditions
Coordinate mode
A display cursor will appear in the center position.
Search coordinate
Search coordinate
A
2.
To change the position, use the Up/Down and Right/Left Keys to move
the cursor.
3.
Press the ENT Key to confirm the setting.
The settings will be saved and the screen in (1.) will return.
Search coordinate
changed to a suitable position
(center of model is the default)
280,251