Gravity And Axis; Step 1: Setting The Binary Level - Omron F160 Operation Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Gravity and Axis

3-3

Gravity and Axis

SeeAlso
Operational Flow
STEP 1
STEP 2
Draw
Set the
measurement
binary level.
region.
3-3-1

STEP 1: Setting the Binary Level

90
1.
Select Coordinate mode.
0.Defecr(var. box)
Measurement conditions
Left edge
Upper edge
Right edge
Lower edge
Reference registration
Judgement conditions
Detailed conditions
Coordinate mode
The Coordinate Mode Settings Screen will be displayed.
Coordinate mode
Output coordinate :
After scroll
Calibration
End
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Density images taken by the Camera are converted into binary images made
up of black and white pixels and then measured. The size (area), position
(center of gravity), and axis angle of the white-pixel area is calculated.
Refer to page 7.
(If required)
STEP 3
Re-register
reference
values.
Set the level for converting 256-gradation images into binary images. The
F160 performs measurement for the white areas. Therefore, make the settings
so that the areas for the center of gravity or the axis angle are white.
: OFF
(If required)
STEP 5
STEP 4
Set
Set pixel
judgement
skipping.
conditions.
Section 3-3
STEP 6
Set
coordinate
mode.