Area (Variable Box)
SeeAlso
3-1-7
STEP 7: Setting the Coordinate Mode
Coordinate mode
Output coordinate:
After scroll
Calibration
End
The default settings are marked with asterisks.*
CHECK
1.
Select Detailed conditions.
0.Area(var. box)
Measurement conditions
Left edge
Upper edge
Right edge
Lower edge
Reference registration
Judgement conditions
Detailed conditions
↑ ↓
The Detailed Conditions Settings Screen will be displayed.
Detailed conditions
Skipping X : [ 1]
Skipping Y : [ 1]
End
2.
Set the number of pixels to skip.
Refer to page 29 for details on inputting values.
3.
Select End.
The setting will be registered and the screen in (1.) will return.
Select the type of coordinates.
Before scroll: Output made using the coordinate values
After scroll*: Output made using the coordinate values
Refer to page 197 for position compensation.
Refer to page 322 for differences between output coordinates.
: OFF
ON : Output made using coordinate values set using calibration.
OFF*: Output made using Camera coordinate values.
If the coordinate mode is changed after the judgement conditions have been
set, the measurement results will change also. Change the judgement condi-
tions to enable correct measurement.
before position displacement compensation.
after position displacement compensation.
Refer to page 185 for information on calibration.
Section 3-1
79