Edge Filter - Omron ZX-GT User Manual

Zx-gt series smart sensor
Hide thumbs Also See for ZX-GT:
Table of Contents

Advertisement

Edge Filter

CCD
Edge filter: 3
All judged as interrupted beam sections
Though the Controller
becomes more
susceptible to the
influence of noise,
the edge detection
sensitivity increases.
Setting value
3 to 7 (pixels)
1
Select the special setting.
2
Set the edge filter.
64
Adjusting Detection Conditions
The Controller becomes
more susceptible to the
noise.
CCD
Edge filter: 7
Processed as noise
Judged as interrupted
beam section
Description
Set the number of pixels to function as the edge filter.
The setting differs according to the measurement mode.
• When the wire position measurement mode or glass edge
measurement mode is selected
3 to 7 (default value: 4)
• When another measurement mode is selected
7 (fixed)
Select [SPCL].
Select [M-LV] or [ALL].
Confirm the selection.
Select [EG.FLT].
Change the current value.
Confirm the selection.
The edge filter for judging the interrupted
beam section can be adjusted to suit your
specific measurement requirements and the
measurement object.
On the ZX-GT, the interrupted beam section
is judged according to how many continuous
pixels of the CCD's 2000 pixels in the
receiver are blocked. These continuous
pixels act as the edge filter. By adjusting this
number of edge pixels, you can prevent
noise and increase detection sensitivity.
SUB
SUB
ZX-GT User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zx-gif11aZx-gif11Zx-gif41aZx-gif41

Table of Contents