Customizing Operations
Precaution
SeeAlso
6-5-6

Setting Passwords

SeeAlso
308
If this function is set to OFF and settings data changed, always save the data
before changing scene groups. When scene groups are changed, data from
the flash memory or the Memory Card is loaded. So if the changed settings
data is not saved, the data will be replaced by the loaded data. Refer to
page 267.
1.
Enter System mode and select Operation settings.
Refer to page 284.
The Menu will be displayed.
Set key operation
Display capture
Setting menu masking
Processing item masking
Save at switch Scn Group
Password
2.
Select Save at switch Scn Group.
The Saving at Switch Scn Group Settings Screen will be displayed.
Saving at switch Scn Group
Save :
End
3.
Select ON or OFF.
ON: Saves the data (default)
OFF: Does not save the data
4.
Select End.
The setting will be saved and the screen in (2.) will return.
Passwords can be set to prevent settings being changed through incorrect
operation. Set whether or not a password is required for the following two
operations.
• When moving from Run Mode to Set, Monitor, or other modes.
• When changing scenes in Run Mode.
1.
Enter System mode and select Operation settings.
Refer to page 284.
The Menu will be displayed.
Set key operation
Display capture
Setting menu masking
Processing item masking
Save at switch Scn Group
Password
2.
Select Password.
ON
OFF
ON