10.8.2

Coordinate systems

Configuring a global basic frame
An NC with 2 channels is required. The following applies:
The global basic frame can then be written by either channel.
The other channel recognizes this change when the global basic frame is reactivated.
The global basic frame can be read by either channel.
Either channel can activate the global basic frame for that channel.
Machine data
Machine data
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[0]
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[1]
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[2]
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[3]
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[4]
MD10000 $MN_AXCONF_MACHAX_NAME_TAB[5]
MD18602 $MN_MM_NUM_GLOBAL_BASE_FRAMES
MD28081 $MC_MM_NUM_BASE_FRAMES
Machine data for channel 1
$MC_AXCONF_CHANAX_NAME_TAB[0]
$MC_AXCONF_CHANAX_NAME_TAB[1]
$MC_AXCONF_CHANAX_NAME_TAB[2]
$MC_AXCONF_MACHAX_USED[0]
$MC_AXCONF_MACHAX_USED[1]
$MC_AXCONF_MACHAX_USED[2]
$MC_AXCONF_GEOAX_NAME_TAB[0]
$MC_AXCONF_GEOAX_NAME_TAB[1]
$MC_AXCONF_GEOAX_NAME_TAB[2]
$MC_AXCONF_GEOAX_ASSIGN_TAB[0]
$MC_AXCONF_GEOAX_ASSIGN_TAB[1]
$MC_AXCONF_GEOAX_ASSIGN_TAB[2]
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
K2: Axis Types, Coordinate Systems, Frames
Value
= X1
= X2
= X3
= X4
= X5
= X6
= 1
= 1
Value
Machine data for channel 1
=X
$MC_AXCONF_CHANAX_NAME_TAB[0]
=Y
$MC_AXCONF_CHANAX_NAME_TAB[1]
=Z
$MC_AXCONF_CHANAX_NAME_TAB[2]
= 1
$MC_AXCONF_MACHAX_USED[0]
= 2
$MC_AXCONF_MACHAX_USED[1]
= 3
$MC_AXCONF_MACHAX_USED[2]
=X
$MC_AXCONF_GEOAX_NAME_TAB[0]
=Y
$MC_AXCONF_GEOAX_NAME_TAB[1]
=Z
$MC_AXCONF_GEOAX_NAME_TAB[2]
= 1
$MC_AXCONF_GEOAX_ASSIGN_TAB[0]
= 2
$MC_AXCONF_GEOAX_ASSIGN_TAB[1]
= 3
$MC_AXCONF_GEOAX_ASSIGN_TAB[2]
10.8 Examples
Value
=X
=Y
=Z
= 4
= 5
= 6
=X
=Y
=Z
= 4
= 5
= 6