Execution From External - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

K1: Mode group, channel, program operation, reset response
9.13 Program control
9.13.7

Execution from external

Function
The "Execution from external" function can be used to execute programs that cannot be saved directly in the NC
memory due to memory shortage from an external program memory.
Note
Protected cycles (_CPF files) cannot be processed with this function.
External program memory
External program memory can be found on the following data carriers:
Local drive
Network drive
USB drive
Note
Execution from external source via USB interface
If external programs are to be transferred from an external USB drive via a USB interface,
only the interface via X203 (named "TCU_1") can be used.
A USB FlashDrive cannot be recommended as a persistent storage medium.
Applications
Direct execution from external programs
In principle, any program that is accessible via the directory structure of the interface in the "Execution from
external" HMI mode can be selected and executed.
Execution of external sub-programs from the part program
The external subroutine is called through the part program command EXTCALL with specification of a call
path (optional) and the subroutine identifier ( → see "Execution from external subroutines [Page 625]").
Parameter assignment
A reloading memory (FIFO buffer) must be reserved in the dynamic NC memory for executing a program in the
"Executing from external" mode (main program or subroutine).
Size of FIFO buffer
The size of the FIFO buffer is set in the machine data:
MD18360 $MN_MM_EXT_PROG_BUFFER_SIZE (FIFO buffer size for processing from external)
Default: 30 kbyte
624
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents