P3: Basic PLC Program for SINUMERIK 840D sl
13.8 Structure and functions of the basic program
840D sl: PROFIBUS connection on the MPI/DP port
With the PROFIBUS connection of the MCP, this component must be considered in the STEP 7 hardware
configuration. The MCP is connected on the MPI/DP bus of the PLC.
The addresses must be stored in the input and output log range. These start addresses must also be stored in
the pointer parameters of the FB1. The FB1 parameters listed below are used for further parameter assignment.
There is no PROFIBUS variant of the HHU. For this reason, an Ethernet connection is shown for the HHU in this
diagram. The PROFIBUS slave address must be stored in the MCP1BusAdr and MCP2BusAdr. Enter the pointer
to the configured diagnostic address (e.g. P#A8190.0) in MCPxStatRec.
Figure 13-18 840D sl: PROFIBUS connection on the MPI/DP port
Relevant parameters (FB1)
MCP
MCPNum = 1 or 2 (number of MCPs)
MCP1In
MCP1Out
MCP1StatSend (n.r.)
MCP1StatRec
MCP1BusAdr
MCP1Timeout
MCP1Cycl (n.r.)
MCPMPI = FALSE
MCP1Stop
MCPBusType = b#16#44
MCPSDB210= FALSE
MCPCopyDB77 = FALSE
900
MCP2In
MCP2Out
MCP2StatSend (n.r.)
MCP2StatRec
MCP2BusAdr
MCP2Timeout
MCP2Cycl
MCP2Stop
HHU
HHU = 5 (via CP 840D sl)
BHGIn
BHGOut
BHGStatSend
BHGStatRec
BHGInLen
BHGOutLen
BHGTimeout (n.r.)
BHGCycl (n.r.)
BHGRecGDNo
BHGRecGBZNo (n.r.)
BHGRecObjNo (n.r.)
BHGSendGDNo (n.r.)
BHGSendGBZNo (n.r.)
BHGSendObjNo (n.r.)
BHGMPI = FALSE
BHGStop