R1: Reference point approach
15.6 Referencing with distancecoded reference marks
15.6.3
Chronological sequence
Chronological sequence
Referencing with distance-coded reference marks can be divided into two phases:
•
Phase 1: Travel across the reference marks with synchronization
•
Phase 2: Traveling to a fixed destination point
Figure 15-13
Distancecoded reference marks
15.6.4
Phase 1: Travel across the reference marks with synchronization
Phase 1: Start
For information on starting reference point approach, refer to "Axis-specific referencing" and "Channel-specific
referencing."
reference cam
In measuring systems with distance-coded reference marks, reference cams are not required for the actual
referencing action. For functional reasons, however, a reference cam is required for channel-specific reference
point approach and reference point approach from the part program (G74) before the traversing range end of the
machine axis.
1224
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions