K2: Axis Types, Coordinate Systems, Frames
10.5  Frames 
Frame conditions after RESET / parts program end
Frame
Programmable frame
Settable frames
Complete basic frame
System frames
External zero offset
DRF offset
Deletion of system frames
The system frames in the data management can be deleted during RESET uisng machine data:
MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK (deletion of system frames during RESET)
Bit
Significance
0
System frame for actual value setting and scratching is deleted during RESET.
1
System frame for zero offset external is deleted during RESET.
2
Reserved, for TCARR and PAROT see MD20150 $MC_GCODE_RESET_VALUES[ ].
3
Reserved, for TOROT and TOFRAME see MD20150 $MC_GCODE_RESET_VALUES[ ].
4
System frame for workpiece reference points is deleted during RESET.
5
System frame for cycles is deleted during RESET.
6
Reserved, RESET response depends on MD20110 $MC_RESET_MODE_MASK.
7
System frame for $P_ISO1FR is deleted during RESET.
8
System frame for $P_ISO2FR is deleted during RESET.
9
System frame for $P_ISO3FR is deleted during RESET.
10
System frame for $P_ISO4FR is deleted during RESET.
11
System frame $P_RELFR is deleted during RESET.
798
condition after RESET / part program end
Deleted.
Retained, depending on
MD20110 $MC_RESET_MODE_MASK
and
MD20152 $MC_GCODE_RESET_MODE.
Retained, depending on:
MD20110 $MC_RESET_MODE_MASK Bit 0 and Bit 14,
MD10613 $MN_NCBFRAME_RESET_MASK
and
MD24002 $MC_CHBFRAME_RESET_MASK.
Retained, depending on
MD24006 $MC_CHSFRAME_RESET_MASK
and
MD20150 $MC_GCODE_RESET_VALUES[ ].
Retained
Retained
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions