P4: PLC for SINUMERIK 828D
14.6 Function interface
14.6.2.2
PI services
PI service ASUB
Initialization
With the ASUB PI service, it is possible to assign the interrupt numbers 1 and 2 fixed program names from the
PLC. Precondition for this is the existence of the programs
directory.
PI index
Function
1
Assignment of Interrupt 1 to the CMA_DIR/
PLCASUP1_SPF program.
2
Assignment of Interrupt 2 to the CMA_DIR/
PLCASUP2_SPF program.
The following must be taken into account during the initialization:
•
The PI service ASUB only has to be executed once after a restart and it is then kept.
•
An initialization may only be performed when the channel is inactive.
•
If a "power up" is configured as the initiating event for the events-triggered program call, initialization must
only be started after the end of the event-triggered program.
Relevant PI parameters for PI services 1 and 2
PI parameter
Address
1
DB1200.DBW4004
2
DB1200.DBW4006
PI service LOGOUT
Reset password
The password last transferred to the NCK is reset.
PI index
3
Relevant PI parameters for PI service 3
None
1166
Signal
LIFTFAST
BLSYNC
Function
Reset password
PLCASUP1_SPF
PLCASUP2_SPF
or
Interrupt priority
1
2
Valid values
0/1
0/1
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
in the CMA
Basic Functions