Table 2-8 Sip Trunk User Name / Password - Tadiran Telecom TGW4 SERIES User Configuration Manual

Table of Contents

Advertisement

User Configuration Manual
Name
*
Proxy server
Subdomain
name
*
Registrar mode
*
User name
*
Registrar
password
Registration
expiration
Table 2-8 below is used in section 3.3 FXO Trunk Line – Basic Configuration (TGW8-2G) on page 90.
SIP Trunk User name / Password
Table 2-8
Name
Trunk user name
Trunk password
20
Description
Configure the IP address and port number of the SIP proxy server. The address and port
number are separated by ":". It has no default value.
The proxy server address can be set to an IP address or a domain name. e.g.
168.33.134.51:5000 or www.sipproxy.com:5000.
When a domain name is used, you must activate DNS service and configure DNS server
parameters on the network-configuration page.
When a domain name is used, you can fill in a backup IP address in Backup SIP proxy
server in the High Availability configuration. This allows the TGW to failover to the IP
address if the domain name resolution service fails.
For Aeonix  Enter the Aeonix server IP address or name
(ex. 172.28.1.260 or tdd.tad.com).
This domain name will be used in INVITE messages. If it is not set here, the gateways
will use the IP address or domain name of the proxy server as the user-agent domain
name. It has no default value.
The gateway supports three registration schemes:
Per line (default): authentication and register per line
Per gateway: authentication and register per gateway
Per line/GW auth: Enable registration per line. Use the number configuration per line.
Use the global account and password in authentication
For Aeonix  Select Per line
Configure the user name as part of the account for registration. It has no default value.
Note: If Per gateway or Per line/GW Auth is selected for Registrar mode, the user
name must be entered here. If per line is selected, the user name should be set on "Line >
Feature" page (Refer to
Subscriber Line Features
For Aeonix  In the User name box, enter the Trunk user name.
Use Table 2-8 below as a worksheet to make a list of Trunk User Name/Password.
Password as part of account information is used for authentication by platform. It has no
default value. It is formed with either numbers or characters, and is case sensitive.
Note: If Per gateway or Per Line/GW Auth is selected for Registrar mode, the
password must be entered here. If Per line is selected, the password should be set on
"Line > Feature" page (Refer to
For Aeonix  In the Password box, enter the Trunk password.
Use Table 2-8 below as a worksheet to make a list of Trunk User Name/Password.
Valid time of SIP re-registration in seconds. Its default value is 600 sec.
Enter value (see User name and Registrar password, above)
TGW4/8 Gateway Series for Aeonix
on page 27).
on page 27).
Subscriber Line Features