Part No. 122985
Hydraulic Component
Specifications
Drive pump
Type: bi-directional variable displacement piston pump
Displacement
Flow rate @ 2300 rpm
Drive pressure, maximum
Charge pump
Type:
Displacement
Flow rate @ 2300 rpm
Charge pressure @ 2300 rpm
Neutral position
Function pump
Type:
Displacement
Flow rate @ 2300 rpm
Auxiliary pump
Type:
Displacement - static
Continuous improvement of our products is a
Genie policy. Product specifications are subject
to change without notice.
S-80 • S-85 • S-80X
Section 2 • Specifications
SPECIFICATIONS
0 to 2.8 cu in
0 to 46 cc
0 to 30.3 gpm
0 to 114.7 L/min
0.85 cu in
34.1 L/min
variable displacement piston pump
0 to 2.3 cu in
0 to 38 cc
0 to 23 gpm
0 to 87 L/min
fixed displacement gear pump
0.151 cu in
3750 psi
259 bar
gerotor
13.9 cc
9 gpm
310 psi
21.4 bar
2.47 cc
2 - 3