Section 5 • Fault Codes
FAULT CODES
Error Source
ID
Name
31
Primary
Ext. / Ret.
Joystick
32
Primary
Ext. / Ret.
Directional
Valves
33
Primary
Ext. / Ret.
Flow
Valve
34
Ext. Ret.
Limit Switch
Cross Check
41
Turntable
Rotate
Joystick
5 - 4
Error Type
ID
Name
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
31
Invalid setup
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
S-80 • S-85 • S-80X
Condition
Function is
inoperative.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Limited speed
and direction
frozen at zero
and neutral.
Alarm sounds
indicating a fault.
February 2011
Solution
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
correted.
Cycle power off,
then on after
problem has been
corrected.
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.