Genie S-80 Service Manual page 169

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

February 2011
Error Source
ID
Name
21
Primary
Up / Down
Joystick
22
Primary
Up / Down
Directional
Valves
23
Primary
Up / Down
Flow Valve
24
Angle sensor
26
Angle sensor
cross check
(S-80X)
Part No. 122985
Error Type
ID
Name
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
31
Invalid setup
19
Out of range
S-80 • S-85 • S-80X
Condition
Function is
inoperative.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Reduced speed
function.
Alarm sounds
indicating a fault.
Section 5 • Fault Codes
FAULT CODES
Solution
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
correted.
Cycle power off,
then on after
problem has been
corrected.
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
corrected.
Calibrate angle sensor.
Continued on next page
5 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-80xS-85

Table of Contents