Hydraulic Component Specifications - Genie S-100 Service And Repair Manual

Hide thumbs Also See for S-100:
Table of Contents

Advertisement

Section 2 • Specifications
SPECIFICATIONS
Petro-Canada Environ MV 46
Fluid Properties
ISO Grade
Viscosity index
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
Flash point
Pour point
Maximum continuous operating
temperature
UCON Hydrolube HP-5046 Fluid
Properties
ISO Grade
Viscosity index
Kinematic Viscosity
cSt @ 149°F / 65°C
cSt @ 104°F / 40°C
cSt @ 0°F / -18°C
Flash point
Pour point
Maximum continuous operating
temperature
2 - 8
Hydraulic Component
Specifications
Drive pump
46
154
Type:
Displacement
8.0
44.4
Flow rate @ 2350 rpm, maximum
482°F / 250°C
-49°F / -45°C
Drive pressure, maximum
180°F / 82°C
Charge pump
Type:
Displacement
Flow rate @ 2350 rpm
46
Charge pressure @ 2350 rpm
192
Neutral position
22
46
Function pump
1300
Type:
None
Front Section
-81°F / -63°C
Displacement
189°F / 87°C
Flow rate @ 2350 rpm, maximum
S-100 • S-105 • S-120 • S-125
bi-directional variable displacement piston pump
variable displacement piston pump
March 2017
0 to 2.8 cu in
0 to 46 cc
28.5 gpm
108 L/min
3625 psi
250 bar
gerotor
0.85 cu in
13.9 cc
9 gpm
34 L/min
315 psi
21.7 bar
0 to 1.71 cu in
0 to 28 cc
17.4 gpm
65.9 L/min
Part No. 1268494

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-120S-105S-125