Inspect The Electrical Wiring - Genie S-80 Service Manual

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

February 2012
10 Check the ambient air temperature and adjust
the specific gravity reading for each cell as
follows:
• Add 0.004 to the reading of each cell for
every 10° / 5.5° C above 80° F / 26.7° C.
• Subtract 0.004 from the reading of each cell for
every 10° / 5.5° C below 80° F / 26.7° C.
Result: All battery cells display a specific gravity
of 1.277 or greater. The battery is fully charged.
Proceed to step 11.
Result: The difference in specific gravity
readings between cells is greater than 0.1 OR
the specific gravity of one or more cells is less
than 1.177. Replace the battery.
11 Check the battery acid level. If needed,
replenish with distilled water to
below the bottom of the battery fill tube. Do not
overfill.
12 Install the vent caps and neutralize any
electrolyte that may have spilled.
Part No. 122985
B-2

Inspect the Electrical Wiring

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
1
/
inch / 3 mm
8
1 Open the turntable cover at the engine side of
2 Remove the engine tray retaining fastener.
a
S-80 • S-85 • S-80X
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
Electrocution/ burn hazard.
Contact with hot or live circuits
could result in death or serious
injury. Remove all rings, watches
and other jewelry.
the machine.
Swing the engine tray out away from the
machine.
a
engine tray anchor hole
b
engine tray retaining fastener
b
3 - 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-80xS-85

Table of Contents