Drive Motor - Genie S-80 Service Manual

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

Section 4 • Repair Procedures
4WD STEER AXLE COMPONENTS
12-2

Drive Motor

How to Remove a Drive Motor
Component damage hazard.
Repairs to the motor should only
be performed by an authorized
Sauer dealer.
Component damage hazard. The
work area and surfaces where this
procedure will be performed must
be clean and free of debris that
could get into the hydraulic system
and cause severe component
damage. Dealer service is
recommended.
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or the
hose end must be replaced. All connections must
be torqued to specification during installation.
Refer to Section 2, Hydraulic Hose and Fitting
Torque Specifications .
1 Extend the axles.
2 Remove the drive motor access covers from
both sides of the inner axle.
4 - 70
3 Tag, disconnect and plug the hydraulic hoses
from the drive motor. Cap the fittings on the
drive motor.
4 Remove the drive motor mounting fasteners.
5 Slide the drive motor shaft out of the drive hub,
and remove the drive motor from the machine.
Refer to Section 2, Specifications .
S-80 • S-85 • S-80X
February 2012
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
Part No. 122985

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-80xS-85

Table of Contents