Genie S-80 Service Manual page 171

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

February 2011
Error Source
ID
Name
42
Turntable
Rotate
Directional
Valves
43
Turntable
Rotate
Flow Valve
44
Drive Enable
Override
Switch
51
Drive Joystick
Part No. 122985
Error Type
ID
Name
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
21
Fault
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
S-80 • S-85 • S-80X
Condition
Limited direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Drive enable
override direction
is frozen at
neutral.
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Section 5 • Fault Codes
FAULT CODES
Solution
Cycle power off,
then on after
problem has been
corrected.
Cycle power off,
then on after
problem has been
correted.
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
corrected.
Cylcle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Continued on next page