Genie S-80 Service Manual page 172

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

Section 5 • Fault Codes
FAULT CODES
Error Source
ID
Name
53
Drive Flow
Valve (EDC)
54
Drive Brake
Valve
55
High Drive
Motor Speed
Valve
61
Steer Joystick
62
Steer
Directional
Valve
5 - 6
Error Type
ID
Name
12
Value too high
15
Value too low
Frozen at zero
and neutral.
17
Not calibrated
21
Fault
21
Fault
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
S-80 • S-85 • S-80X
Condition
Limited speed
and direction.
problem has been
corrected.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Drive frozen
at zero and
neutral.
Alarm sounds
indicating a fault.
Motor speed
in the low state.
Alarm sounds
indicating a fault.
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
February 2011
Solution
Cycle power off,
then on after
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
correted.
Cycle power off,
then on after
problem has been
corrected.
Cylcle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
corrected.
Part No. 122985

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-80xS-85

Table of Contents