Section 5 • Fault Codes
FAULT CODES
System
Code Fault Name
MAP
108 MAP Pressure High
107 MAP Voltage Low
ECT/
118 ECT Voltage High
CHT
117 ECT Voltage Low
116 ECT higher than expected 1
217 ECT higher than expected 2
IAT
113 IAT Voltage High
112 IAT Voltage Low
111 IAT higher than expected 1
127 IAT higher than expected 2
BP
2229 BP Pressure High
129 BP Pressure Low
Battery
563 Voltage High
Voltage
562 Voltage Low
5V
643 5VE1 High Voltage
External
642 5VE1 Low Voltage
TPS
123 TPS1 High Voltage
122 TPS1 Low Voltage
223 TPS2 High Voltage
222 TPS2 Low Voltage
221 TPS1 > than TPS2
121 TPS1 < than TPS2
2112 Unable to reach > TPS
2111 Unable to reach < TPS
2135 TPS1/2 simultaneous
voltages out of range
* Adaptive Learn Key Cycle
5 - 8
Fault Conditions
Y Y
MAP pressure > 16 psi and TPS < 10%
and RPM > 1800
To Unlatch, MAP pressure must be < 10 psi
Y Y
MAP voltage < 0.05 vdc and TPS > 2%
and RPM < 7000
To Unlatch, MAP voltage must be > 0.5 vdc
Y
ECT voltage > 4.95 vdc
Y
ECT voltage < 0.05 vdc
Y Y Y
ECT > 210 ° F and RPM > 600
Y
ECT > 230 ° F and RPM > 600
Y
IAT voltage > 4.95 vdc
Y
IAT voltage < 0.05 vdc
Y
Y
IAT > 200 ° F and RPM > 1000
Y
IAT > 210 ° F and RPM > 1000
Y Y
BP pressure > 16 psi
Y Y
BP pressure < 8.3 psi
Y Y
Voltage > 18 vdc
Y Y
Voltage < 9.5 vdc and RPM > 1500
Y
5VE1 > 5.4 vdc
Y
5VE1 < 4.6 vdc
Y
TPS1 voltage > 4.8 vdc
Y
TPS1 voltage < 0.2 vdc
TPS2 voltage > 4.8 vdc
Y
Y
TPS2 voltage < 0.2 vdc
Y
(TPS1 percent - TPS2 percent) > 20%
Y
(TPS1 percent - TPS2 percent) < -20%
Y
(target TPS - actual TPS) > 20%
(target TPS - actual TPS) < -20%
Y
Y
Uses same parameters as individual
TPS1/2 voltage fault detection above