6.4 SCANNING

6.4.1 OVERVIEW
1
1. Exposure Lamp
2. 1st Scanner
3. Exposure Glass
4. Lens Block
The original is illuminated by the exposure lamp (a xenon lamp). The image is
reflected onto a CCD (charge coupled device) on the lens block via the 1st, 2nd,
and 3rd mirrors, and through the lens on the lens block.
The 1st scanner consists of the exposure lamp, a reflector, and the 1st mirror.
A lamp stabilizer energizes the exposure lamp. The light reflected by the reflector is
of almost equal intensity, to reduce shadows on pasted originals.
An optics anti-condensation heater is available as an option. It can be installed on
the left side of the scanner. It turns on whenever the power cord is plugged in.
Lamp Stabilizer Fuse
ICP1
DC50 V/1.5 A
SM
2
3
7
Rating
Manufacturer
ROHM CO.,LTD
6-9
4
6
5. Scanner Motor
6. Original Length Sensor
7. Original Width Sensors
8. Scanner H.P. Sensor
B121D928.WMF
Type No.
ICP–N38
B121 Series/B259 Series
SCANNING