Ricoh B121 Service Manual page 205

Hide thumbs Also See for B121:
Table of Contents

Advertisement

Remote Service
5816*
5816 1
I/F Setting
Enables or disables the remote diagnostics function.
5816 2
CE Call
Allows the customer representative to start or end the remote machine check using
CSS or NRS by pressing the center report key.
5816 3
Function Flag
Enables or disables remote diagnosis via the NRS network.
5816 6
Device Information Call Display
Determines whether the device information call (NRS) is displayed.
5816 7
SSL Disable
Determines whether the SSL sends the remote-communication-gate confirmation.
5816 8
RCG Connect Timeout
Sets the timer for the remote-communication-gate connection (NRS).
5816 9
RCG Write to Timeout
Sets the timer for writing data to the remote communication gate (NRS).
5816 10
RCG Read Timeout
Sets the timer for reading data from the remote communication gate (NRS).
5816 11
Port 80 Enable
Determines whether permission is granted for access to the SOP via Port 80
(NRS).
5821*
Remote Service Address
5821 1*
CSS PI Device Code
5821 2*
RCG IP Address
5824
NVRAM Upload
5824 1
5.1.11
5825
NVRAM Download
1
5.1.11
5828*
Network Setting
5828 74*
Delete Password
Deletes the NCS (Network Control Service) password. Sets the Telnet, WSM (Web
Status Monitor), and remote ROM update passwords to NULL (empty)
5828 84*
Print Settings List
Prints a list of the NCS parameter settings.
5828 90*
TELNET (0:OFF 1:ON)
Disables or enables Telnet operation. If this SP is disabled the Telnet port is closed.
5828 91*
Web (0:OFF 1:ON)
Disables or enables the Web operation.
SM
SERVICE PROGRAM MODE
[0=Remote diagnostics off/1=Serial (CSS or NRS)
remote diagnostics on/2=Network remote diagnostics]
[0 = Disabled / 1 = Enabled]
[0 = Disabled / 1 = Enabled]
[0 = Disabled / 1 = Enabled]
[1∼ 90 / 10 / 1 second/step]
[0∼ 100 / 60 / 1 second/step]
[0∼ 100 / 60 / 1 second/step]
Japan Only.
Sets the PI device code. After changing this setting,
you must switch the machine off and on.
Sets the IP address of the RCG (Remote
Communication Gate) destination for call processing at
the remote service center.
[00000000h ~ FFFFFFFFh/ 00000000h /
[0 = Disabled / 1 = Enabled]
[0 = Disabled / 1 = Enabled]
5-45
B121 Series/B259 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B259B260B261B122B123

Table of Contents