Ricoh B121 Service Manual page 153

Hide thumbs Also See for B121:
Table of Contents

Advertisement

No.
Definition
998
B
Application start error
After power on, the application does not
start within 60 s. (All applications
neither start nor end normally.)
999
B
Program download error
The download (program, print data,
language data) from the IC card does
not execute normally.
SM
Symptom
4-11
SERVICE CALL CONDITIONS
Possible Cause
• Download controller firmware
• Replace the controller board
• An option required by the application
(RAM, DIMM, board) is not installed
• Board installed incorrectly
• BICU board defective
• Controller board defective
• IC card defective
• NVRAM defective
• Loss of power during downloading
Important Notes About SC999
• Primarily intended for operating in
the download mode, logging is not
performed with SC999.
• If the machine loses power while
downloading, or if for some other
reason the download does not end
normally, this could damage the
controller board or the PCB targeted
for the download and prevent
subsequent downloading. If this
problem occurs, the damaged PCB
must be replaced.
B121 Series/B259 Series