ADF APS SENSOR OUTPUT DISPLAY (SP6-901)

Sensor Positions

Large < ・・・・・・・・・・・・・ > Small
W1
1
0
W2
0
0

Reading Data

W1
W2
0
0
0
0
0
1
0
1
1
1
1
0
1
0
1
1
1
1
1: Detected
SETTING DAYLIGHT SAVINGS TIME (SP5307)
Digit Position
7
Month: 01 through 12
6
5
Week of the Month: 1 through 5
4
Day of the Week: 0 through 7
3
Hours:
2
1
Start and Stop 1hour 0 minutes
0
Example- April 4, 2004 DST is turned ON and October 31, 2004 DST is turned OFF:
04/04 2:00 AM DST is turned ON- "4100210" (7digits) There is no leading 0. See 2-1 below.
1- SP5-307-001: Change 0(=OFF) to 1(=ON)
2- SP5-307-003(Summer time start):
2-1. Enter 04 as month of April. (4 will be displayed. The leading 0 will not be displayed.)
st
2-2. Enter 1 (=1
week) and 0 (=Sunday)
2-3. Enter 02 (=2:00 AM)
2-4. Enter 10 (=1 hour 0 minute)
3- SP5-307-004(Summer time end): 10/31 2:00 AM DST is turned OFF: "10500200" (8 digits)
3-1. Enter 10 as month of October. (10 will be entered.)
3-2. Enter 5 (=5th) and 0 (=Sunday)
3-3. Enter 02 (=2:00 AM)
3-4. Enter 00.
Remember to turn the main switch OFF and ON when the message is displayed.
SM
0
1
1
1
L1
L2
0
0
1
1
0
0
81/2" x 51/2" LEF
1
0
81/2" x 11" SEF
1
1
0
0
11" x 81/2" LEF
1
1
0
0
51/2" X 81/2" SEF
1
0
Jan. = 01, Feb. =02, etc.
1st week =1, 2nd week =2, 3rd week = 3, etc.
Sun.= 0, Mon. = 1, Tue. = 2, etc.
00 = Midnight, 01 = 1 AM, 02 = 2 AM through
23 = 11 PM
For SP5307-3, this must always be 10. For
SP5307-4, this value must always be 00.
5-89
SERVICE PROGRAM MODE
Paper Size
NA
EU/AA
B5 LEF
11" x 17"
A5 LEF
A4 SEF
81/2" x 14"
81/2" x 13"
A4 LEF
11" x 17"
A5 SEF
B5 SEF
B121 Series/B259 Series
B121S921.WMF
B4
A3

Advertisement