SERVICE PROGRAM MODE
5307*
Summer Time
5307 1
Summer Time On/Off
Enables or disables the daylight saving time settings in SP5-307-3 and 4.
OFF = 0, ON = 1
5307 3
Summer Time Start (
Specifies the start of the daylight saving time.
5307 4
Summer Time End (
Specifies the end of the daylight saving time.
5404*
User Code Count Clear
5404 1
Initializes the user code counter.
5501*
PM Alarm Interval
5501 1
PM Alarm Interval (Printout)
Specifies when the PM alarm occurs.
5501 2
PM Alarm Original Count Alarm
Enables or disables the original count alarm.
5504*
Jam Alarm
5504 1
Sets the alarm to sound for the specified jam level (document misfeeds are not
included).
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505*
Error Alarm
5505 1
Specifies the number of paper (in hundred) used as the error alarm level. The error
alarm starts if 5 SC codes (or more) are generated before the copier prints the
specified number of paper. When the copier has printed the specified number of
paper, the SC code counter (of this SP) is cleared to zero.
5507*
Supply Alarm
5507 1
Paper Supply Alarm
5507 3
Toner Supply Alarm
5507 128
Interval :Others
5507 132
Interval :A3
5507 133
Interval :A4
5507 134
Interval :A5
5507 141
Interval :B4
5507 142
Interval :B5
5507 160
Interval :DLT
5507 164
Interval :LG
5507 166
Interval :LT
5507 172
Interval :HLT
B121 Series/B259 Series
5.1.18)
5.1.18)
[0 ~ 9999 / 0 / 0K copies/step]
[0 = Off / 1 = On]
[0 ~ 255 / 20 / 1 hundred sheets/step]
0: Off, 1: On, DFU
0: Off, 1: On, DFU
[00250 ~ 10000 / 1000 / 1 Step] DFU
5-42
Rev. 04/2004
SM