Ricoh B121 Service Manual page 501

Hide thumbs Also See for B121:
Table of Contents

Advertisement

Switch 02
No
FUNCTION
0
Initial Tx modem rate
to
Bit 3
2 1 0 Setting (bps)
3
0 0 0 0 Not used
0 0 0 1 2,400
0 0 1 0 4,800
0 0 1 1 7,200
0 1 0 0 9,600
0 1 0 1 12,000
0 1 1 0 14,400
0 1 1 1 16,800
1 0 0 0 19,200
1 0 0 1 21,600
1 0 1 0 24,000
1 0 1 1 26,400
1 1 0 0 28,800
1 1 0 1 31,200
1 1 1 0 33,600
1 1 1 1 Disabled
Other settings: Not used
4-5
Not used
6
AI short protocol
0: Off
1: Disabled
7
Not used
SM
DEDICATED TRANSMISSION PARAMETERS
COMMENTS
If training with a particular remote terminal always
takes too long, the initial modem rate may be too
high. Reduce the initial Tx modem rate using these
bits.
For the settings 14.4 or kbps slower, Switch 04 bit 4
must be changed to 0.
Note: Do not use settings other than listed on the
left.
If the setting is "Disabled", the bit switch setting is
used.
Do not change the settings.
Refer to Appendix B in the Group 3 Facsimile
Manual for details about AI Short Protocol.
If the setting is "Disabled", the bit switch setting is
used.
Do not change the settings.
63
B620

Advertisement

Table of Contents
loading

This manual is also suitable for:

B259B260B261B122B123

Table of Contents