CHAPTER 12

Grounding the SRX240 Services Gateway

SRX240 Services Gateway Grounding Specifications

Related
Documentation
Copyright © 2015, Juniper Networks, Inc.
SRX240 Services Gateway Grounding Specifications on page 59
Grounding the SRX240 Services Gateway on page 60
To meet safety and electromagnetic interference (EMI) requirements and to ensure
proper operation, the services gateway must be adequately grounded before power is
connected. A grounding lug available on the rear of the services gateway chassis is used
to connect the device to earth ground.
WARNING:
Before device installation begins, a licensed electrician must
attach a cable lug to the grounding and power cables that you supply. A cable
with an incorrectly attached lug can damage the device (for example, by
causing a short circuit).
To ground the device before connecting power, you connect the grounding cable to earth
ground and then attach the lug on the cable to the chassis grounding point with the
screw.
Table 32 on page 59
lists the specifications of the grounding cable used with the device.

Table 32: Grounding Cable Specifications for the Services Gateway

Grounding Requirement
Grounding cable
Amperage of grounding cable
Grounding lug
SRX240 Services Gateway Site Electrical Wiring Guidelines on page 35
Grounding the SRX240 Services Gateway on page 60
Specification
14 AWG single-strand wire cable
Up to 25 A
Ring-type, vinyl-insulated TV14-6R lug or
equivalent
59