SRX240 Services Gateway Hardware Guide
110
Table 41: Component LEDs on the SRX240 Services Gateway (continued)
LED
State
DC Power
Green
System Feeds
LEDs
Red (blinking)
Red (steady)
Off
Meaning
Output is normal.
The port has detected a
failure.
The port has detected a
failure.
No output
Copyright © 2015, Juniper Networks, Inc.
Possible Causes and
Corrective Actions
Normal condition. No action
is required.
Input is connected but has
failed because the power
supply fuse has failed or the
input voltage is low.
Verify that the source
circuit breaker has the
proper current rating.
Each power supply must
be connected to a
separate source circuit
breaker.
Check whether the DC
power cables from the
power source to the
device are not damaged.
If the insulation is
cracked or broken,
immediately replace the
cable.
Contact the Juniper
Networks Technical
Assistance Center
(JTAC). See
"Juniper
Networks Technical
Assistance Center" on
page
118.
Both inputs are normal but
no output because of
output side failure or open
connection.
Connect the power
supply feeds to a
different power source
with a new power cables.
Contact the Juniper
Networks Technical
Assistance Center
(JTAC). See
"Juniper
Networks Technical
Assistance Center" on
page
118.
Normal condition if the
services gateway is
switched off. No action is
required.