Monitoring the SRX240 Services Gateway Power System

Monitoring the SRX240 Services Gateway AC Power System

Copyright © 2015, Juniper Networks, Inc.
This topic includes the following sections:
Monitoring the SRX240 Services Gateway AC Power System on page 115
Monitoring the SRX240 Services Gateway DC Power System on page 116
The LEDs on the SRX240 Services Gateway enable you to determine its performance
and operation. The Power LED, located on the front panel of the services gateway,
indicates different conditions with respect to the power system.
Table 43 on page 115
describes different Power LED indications and the required corrective
actions.

Table 43: Services Gateway Power LED Status

LED Status
Green
Yellow
Off
Possible Cause and Corrective
Meaning
Action
The services gateway is
Normal indication. No action is required.
receiving power, and the
internal power supply is
functional.
The Power button has
Normal indication. No action is required.
been pressed and quickly
released. The services
gateway is shutting down
or starting up.
The services gateway is
not receiving power.
Chapter 17: Troubleshooting Components
Verify that the AC power cord from
the power source to the services
gateway is not damaged. If the
insulation is cracked or broken,
immediately replace the cord or
cable.
Ensure that the socket you plug in is
in working condition.
Ensure the services gateway has an
AC input voltage between 110 and
240 VAC.
If you cannot determine the cause
of the problem or need additional
assistance, contact the Juniper
Networks Technical Assistance
Center (JTAC).
See
"Juniper Networks Technical
Assistance Center" on page
118.