Grounding The Srx240 Services Gateway; Figure 14: Grounding The Srx240 Services Gateway; Table 33: Grounding Cable Specifications For The Services Gateway - Juniper SRX240 Hardware Manual

Hide thumbs Also See for SRX240:
Table of Contents

Advertisement

SRX240 Services Gateway Hardware Guide

Grounding the SRX240 Services Gateway

60
SRX240 Services Gateway AC Power Specifications and Requirements on page 37
SRX240 Services Gateway Power Supply on page 25
The following tools and parts are required for grounding the SRX240 Services Gateway:
Grounding cable for your services gateway—The grounding cable must be minimum
14 AWG (2 mm²), minimum 90°C wire, or as permitted by the local code.
Grounding lug—Ring-type, vinyl-insulated TV14-6R lug or equivalent for your grounding
cable
Washers and 10-32x.25-in. screws to secure the grounding lug to the protective earthing
terminal
Phillips (+) screwdrivers, numbers 1 and 2
Figure 14 on page 60
shows the SRX240 grounding point.

Figure 14: Grounding the SRX240 Services Gateway

You ground the device by connecting a grounding cable to earth ground and then attaching
it to the chassis grounding points using one M3 screw.
Table 33 on page 60
lists the specifications of the grounding cable used with the device.

Table 33: Grounding Cable Specifications for the Services Gateway

Grounding Requirement
Grounding cable
Amperage of grounding cable
Grounding lug
Specification
14 AWG single-strand wire cable
Up to 4 A
Ring-type, vinyl-insulated TV14-6R lug or
equivalent
Copyright © 2015, Juniper Networks, Inc.