Card Hopper Empty Sensor - DataCard CP60 Service Manual

Hide thumbs Also See for CP60:
Table of Contents

Advertisement

Card Hopper Empty Sensor

The Input Hopper Empty Option has a bracket that clips onto the Card Tray. The
sensor fits into the bracket and plugs into the J40 connector labeled Spare.
used only by the printer driver API and is not reported to the driver; it will
have no affect on the printer or error messages from the driver. The sensor
can be utilized only after a programmer has done custom development to
incorporate it.
Removal Procedure
1.
Unplug the printer.
2.
Remove the
3.
Unplug the Hopper Empty sensor from the J40 connector labeled Spare. The
plug is located below the CAM Motor.
4.
Pull the wire free from the printer.
5.
Unclip the sensor bracket from the Card Input Hopper.
Replacement Notes
Use Diagnostics to verify that the sensor is working properly.
6-22
Even though this sensor displays on the Diagnostics Sensor screen, it is
Main Enclosure
(p. 6-8).
Sensor Bracket
Sensor
Removal and Replacement

Advertisement