Duplex Rotational Adjustment

This adjustment sets both the Duplex Home and Duplex Print Return offsets.
These parameters control the rotational position of the flipper as the card enters
or leaves the duplex module. This adjustment is best made with two instances of
the Diagnostics software (start Diagnostics and then start another copy).
Adjustment Procedure
1.
From Diagnostics, select Printer and then Step Test.
2.
Click on the Move duplex to home position button. The flipper will rotate
and re-register at the home position.
3.
Open a second instance of Diagnostics and go to the Printer Values window.
4.
Examine the physical position of the duplex calibration pointer. The proper
location of the pointer is at the letter "E" on the duplex chassis.
5.
Verify the setting by re-homing the duplex in Diagnostics.
6.
Set the other parameters based on the new Home offset. The table below
shows what should be added or subtracted from the Home offset's value. For
example, the Handoff offset should be 77 units larger than the Home offset.
Duplex Home Offset
Duplex Print Return Offset
Duplex Handoff Offset
7.
Save the values to Power-on defaults.
CP60 and CP60 Plus Service Manual
If the pointer is right of the "E", add the number of units to the current
setting (each letter represents 2 units because every other letter is shown).
If the pointer is left of the "E", subtract the number of units from the
current setting.
Parameter
Change
Sample
Baseline
17
Add 6
23
Add 77
94
5-39