Card Input Sensor (With Clear Card)

Removal Procedure
1.
Unplug the printer.
2.
Remove the ribbon cartridge and cleaning roller.
3.
Remove the
4.
Gently lift the sensor up from the bracket.
5.
Unplug the connector from the main control board.
Replacement Notes
When pushing the sensor back into position, use a blunt tool and push only
on the center of the body. Do not push against the wire entry points or crush
the wires.
Make sure the sensor is fully seated. The tip of the sensor should be flush
with the edge of the chassis.
Refer to the
replacement details.
Use Diagnostics to pick cards and verify that the sensor is functional.