DataCard CP60 Service Manual page 198

Hide thumbs Also See for CP60:
Table of Contents

Advertisement

14.
To remove the drive rollers:
A.
B.
Replacement Notes
The magnetic clutch will not fit into the opening if it is rotated incorrectly.
After replacing the flipper assembly in the duplex module, rotate the flipper
until the spring clutch engages the stop tabs (clockwise as viewed from the
motor).
If necessary, adjust the duplex home offset.
Print several test cards to verify that the duplex assembly is functioning
properly.
6-74
Spread the non-gear sidewall of the flipper and pull back on the roller.
Tilt the roller shaft up and withdraw the gear through the opening in the
sidewall.
If you rotate the flipper counterclockwise you can feel the drag of the
spring clutch, but it will not engage the stop tabs.
When the flipper is rotated clockwise, the spring clutch will snap over the
stop tabs and will no longer turn in that direction.
Verify that the clutch is properly engaged. When properly engaged, the
flipper will rotate in only one direction.
Removal and Replacement

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp60 plus

Table of Contents