Downloaded from
www.Manualslib.com
3.
As explained in the Chapter 8 topic, "Power supply fuse" on
page 8-16, remove the power supply cover to access the fuse.
4.
Visually, and with a VOM, check to determine that the fuse is in
working order.
If the fuse is good, but the printer's power supply does not output DC voltages,
proceed to the next topic, "Testing for a shorted motor."
Safety interlocks
The printer features four safety interlock switches:
Front door-opened switch.
Right side door-opened switch.
Left door-opened switch.
Optional Lower Tray Assembly door switch.
When any of the switches are opened, the +24 VDC supply to the motors is shut
down, as well as the high-voltage power supply.
1.
Turn off the printer.
2.
With a VOM, set to measure resistance, test each switch when it is
opened and closed.
3.
Inspect each switch's wiring harness for pinches, nicks or open
connections.
If you find a switch that is defective, replace it.
If the switches work correctly and the DC voltages are correct, then the problem
may be an open or otherwise faulty motor.
manuals search engine
6
Troubleshooting
6-5
Service Manual