Table 3-1
Table 3-1.
Console Interface Main Menu options
Option
IP Configuration/
Setup...
SNMP Configuration...
System
Characteristics...
Switch Configuration...
Console/Comm Port
Configuration...
Identify Unit Numbers
Renumber Stack Units
309985-B Rev 00
describes the CI main menu options.
Description
Displays the IP Configuration/Setup screen (see
page
3-8). This screen allows you to set or modify IP configuration parameters.
Displays the SNMP Configuration screen (see
page
3-13). This screen allows you to set or modify the SNMP read-only
community and read-write community strings, enable or disable the
authentication trap and the link Up/down trap, set the IP address of trap
receivers, and set the trap community strings.
Displays the System Characteristics screen (see
page
3-15). This screen allows you to view switch characteristics, including
number of resets, power status, hardware and firmware version, and MAC
address. This screen also contains three user-configurable fields: sysContact,
sysName, and sysLocation. When the switch is part of a stack configuration, this
screen also displays the base unit identification, the number of units configured
in the stack, and the local unit stack number.
Displays the Switch Configuration Menu screen (see
page
3-18). This menu provides the following configuration options: MAC
Address Table, MAC Address-Based Security, VLAN Configuration, Port
Configuration, MultiLink Trunk Configuration, Port Mirroring Configuration, Rate
Limiting Configuration, IGMP Configuration, Display Port Statistics, and Clear All
Port Statistics.
Displays the Console/Comm Port Configuration screen (see
Port
Configuration" on
modify the console/Comm port parameters, including the console port speed
and password settings for the switch and stack operation.
Only appears when the switch is participating in a stack configuration. When
selected, this option identifies the unit numbering of each unit in a stack
configuration by lighting the corresponding number of Link LEDs for
approximately 10 seconds. For example, in a four-unit stack, unit 1 displays one
Link LED, unit 2 displays two Link LEDs, unit 3 displays three Link LEDs, and
unit 4 displays four Link LEDs. The LED display temporarily overrides any
existing Link LED indications on all unit LED display panels.
Only appears when the switch is participating in a stack configuration. Displays
the Renumber Stack Units screen (see
This screen allows you to renumber the units at any time.
page
3-82). This screen allows you to configure and
"Renumber Stack
Using the Console Interface
"IP
Configuration/Setup" on
"SNMP
Configuration" on
"System
Characteristics" on
"Switch
Configuration" on
"Console/Comm
Units" on
page
(continued)
3-89).
3-5