Using the BayStack 410-24T 10BASE-T Switch
Table 3-1.
Console Interface Main Menu options
Option
Display Hardware Units Displays the Hardware Unit Information screen (see
Spanning Tree
Configuration...
TELNET
Configuration...
Software Download...
Configuration File
Display Event Log
Reset
Reset to Default
Settings
3-6
Description
on
page
3-91). This screen lists the switch models, including any installed MDA
and Cascade modules, that are configured in your standalone or stack
configuration.
Displays the Spanning Tree Configuration Menu (see
Configuration" on
page
Spanning Tree Port Configuration, Display Spanning Tree Switch Settings.
Displays the TELNET Configuration screen (see
page
3-99). This screen allows you to set your switch to enable a user at a
remote console terminal to communicate with the BayStack 410-24T switch as if
the console terminal were directly connected to it. You can have up to four active
TELNET sessions running at one time in either a standalone switch or a stack
configuration.
Displays the Software Download screen (see
page
3-102). This screen allows you to revise the BayStack 410-24T switch
software image that is located in nonvolatile flash memory.
Displays the Configuration File Download/Upload screen (see
File" on
page
3-106). This screen allows you to store your switch/stack
configuration parameters on a TFTP server. You can retrieve the configuration
parameters for automatically configuring a replacement switch or stack with the
same configuration when required.
Displays the Event Log screen (see
Resets the switch with the current configuration settings. This option is followed
by a screen prompt that precedes the action. Enter Yes to reset the switch; enter
No to abort the option:
If the switch is participating in a stack configuration, additional prompts allow
you to choose to reset a specific unit in the stack or the entire stack.
When you select this option, the switch resets, runs a self-test, then displays
the Nortel Networks logo screen. Press [Ctrl]-Y to access the
BayStack 410-24T main menu.
Resets the switch to the factory default configuration settings. This option is
followed by a screen prompt that precedes the action. Enter Yes to reset the
switch to the factory default configuration settings; enter No to abort the option:
If the switch is participating in a stack configuration, additional prompts allow
you to choose to reset a specific unit in the stack or the entire stack.
When you select this option, the switch resets, runs a self-test, then displays
the Nortel Networks logo screen. Press [Ctrl]-Y to access the
BayStack 410-24T main menu.
(continued)
3-91). This menu provides the following options:
"Software
"Display Event
"Hardware Unit
Information"
"Spanning Tree
"TELNET
Configuration" on
Download" on
"Configuration
Log" on
page
3-109).
(continued)
309985-B Rev 00