Remove the air cleaner element from the air cleaner
housing.
Replace the element accordance with the
maintenance schedule.
Also, replace the element any time it is excessively
dirty or damaged.
Installation is in the reverse order of removal.
TORQUE:
Air cleaner housing cover bolt:
2 Nom (0.2 kgfom, 1.4lbfoft)
CRANKCASE BREATHER
NOTE:
Service more frequently when ridden in rain, at full
throttle, or after the motorcycle is washed or over-
turned. Service if the deposits level can be seen in
the transparent section of the breather tube.
The crankcase drain tube is behind the air cleaner
housing.
Remove the drain tube from the air cleaner housing
to empty any deposits.
Reinstall the drain tube.
SPARK PLUG
Disconnect the spark plug caps.
NOTE:
Clean around the spark plug bases with compressed
air before removing, and be sure that no debris is
allowed to enter the combustion chamber.
Remove the spark plugs using the spark plug wrench
or an equivalent.
MAINTENANCE
ELEMENT
Inspect or replace as described in the maintenance
(REAR)
schedule (page 3-3).
3-1